The field proven PowerStation UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-2221" is being used by the Lockheed Martin on the WLD-1 project because of their stringent performance and reliability requirements.
The heavy-duty chassis, occupying only 10.5" (6U) of rack space and 19" depth, has rounded metal corners and rugged handles front and rear, aiding in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.
The internal shielded input transformer provides galvanic isolation with provisions for domestic (115 VAC, CONUS) and optionally for international (230 VAC, OCONUS) input voltages. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The unit also operates as a frequency converter, taking 46-440 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent.
The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. All controls and protective devices are brought to the front and rear panels with critical switches having finger guards. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely.
The rear panel provides barrier terminal blocks for the input and output power. Multiple input and output power panel options are available. Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. The exhaust air is diverted out the rear vent, with alternate air flow directions optional. The "ETI0001-2221" has the added benefit of having field replaceable batteries via a front drawout battery modules. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.
See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1482 for a version of this UPS with an integrated PDU and remote control.
Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.
| OUTPUTS | |
| Output voltage: UPS AC: UPS DC: |
120 VAC true sinewave standard 28 VDC isolated 28 VDC isolated 28 VDC isolated |
| Output rating: UPS Total: DC Outputs: |
2200 VA total including DC outputs, up to 1500 VA AC 5 amps @ 28 VDC 11 amps @ 28 VDC 15 amps @ 28 VDC respectively |
| Non-linear load capacity: UPS | Up to 100% non-linear load capability w/o derating |
| Output voltage regulation: UPS | ± 3.0% static regulation of nominal ± 4.0% dynamic (0 to 50% load step) |
| Overload surge capacity: UPS | 110% for 10 minutes; 125% for 30 seconds |
| Harmonic distortion: UPS | Less than 5.0% into 100% non-linear load |
| Output frequency: UPS | 60 Hz ± 1.0% independent of input frequency 50, 400 or 1000 Hz output available as an option |
| Operational status | Status, load and battery LEDs, w/contacts Adjustable level,+90 dB audible alarm w/on/off |
| AC INPUT | |
| Input voltage selection: | Nominal 115 VAC, optional autoranging input of 85-270 VAC |
| Input voltage tolerance: UPS | 85-135 VAC @ full load without using battery, to 70 VAC @ 75% load |
| Input frequency: | From 46 Hz to 440 Hz standard |
| Input power factor: | Better than 99% typically |
| Input/output isolation: | 2200 VA, up to 120 dB common mode, <1.0 mA leakage |
| Input transient suppression: | Complies with IEEE 587 and UL 1449 |
| Input control/protection: | Guarded 2 pole toggle circuit breaker |
| Input power connection: | Barrier terminal block |
| INTERNAL BATTERY | |
| Internal battery type: | Maintenance free immobilized electrolyte, Flame retardant materials (Oxygen Index 28+) |
| Internal battery life: | Rated for continuous service life of 5 years |
| Internal DC protection: | Front panel mounted fuse standard, breaker optional |
| Internal battery time: | 30+ minutes @ 100% load, 60+ minutes @ 50% |
| Internal battery recharge: | Recharged to nominal in <8 hours |
| Internal battery replacement: | (2) Drawout/plug-in modules from front of unit |
| DISTRIBUTION PANEL | |
| Output circuits: | Four outputs standard, optional configurations |
| Output control: | Guarded toggle circuit breakers |
| Output receptacles: | Barrier terminal blocks |
| MECHANICAL | |
| Dimensions ( H x D x W ): | 10.5 (6U) x 19.1 x 19.0 in (267 x 485 x 483 mm) |
| Rack Slide Mount Patterns: | Jonathan, General Devices patterns, others optional |
| Alternate Mounting Options: | Table, Wall, Floor, Portable, Horizontal/Vertical |
| Unit weight: UPS w/o Battery Internal Battery Module |
95 lb. (43 kg) UPS with lift handles front and rear 64 lb. (29 kg) Each Battery Module |
| Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
| Cooling type: | High capacity, positive pressure, forced air |
| Cooling air direction: | Front intake, exhaust to rear, others optional |
| Air intake filter: | Washable metal filter media, others optional |
| ENVIRONMENTAL | |
| Storage temperature: | -40° to 158° F ambient (-40° to 70° C) |
| Operating temperature: | 32° to 126° F ambient ( 0° to 52° C), lower/ higher optional |
| Operating humidity: | 0 to 95% relative humidity (non-condensing) |
| Storage elevation: | Up to 40,000 ft (12,192 m) |
| Operating elevation: | Up to 10,000 ft (3,048 m), higher optional |
| STANDARDS | |
| United States: | Meets UL-1778 standard for UPS equipment, MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000 |
| Canada: | CSA C22.2 No. 107 UPS safety requirements |
| EMI Protection: | EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 |
| OPTIONAL ACCESSORIES | |
| Autoranging International Input, Cold Start, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits | |