The Standard in Rugged Power Products

ETI0001-1479 1.0 kVA
   
Home Up All of these products are manufactured by ETI in the United States.

Up
ETI0001-1402 1.5 kVA
ETI0001-1403 1.5 kVA
ETI0001-1406 3.0 kVA
ETI0001-1417 1.5 kVA
ETI0001-1419 2.0 kVA
ETI0001-1420, 1.0 kVA
ETI0001-1429 2.4 kVA
ETI0001-1437 2.0 kVA
ETI0001-1438 2.0 kVA
ETI0001-1439 4.0 kVA
ETI0001-1442 4.0 kVA
ETI0001-1443 2.0 kVA
ETI0001-1444 2.0 kVA
ETI0001-1445 2.0 kVA
ETI0001-1447 2.0 kVA
ETI0001-1450 2.0 kVA
ETI0001-1451 4.0 kVA
ETI0001-1451AA 4.0 kVA
ETI0001-1452 4.0 kVA
ETI0001-1452AA 4.0 kVA
ETI0001-1453 4.0 kVA
ETI0001-1455 4.0 kVA
ETI0001-1456 4.0 kVA
ETI0001-1458 2.0 kVA
ETI0001-1467 2.0 kVA
ETI0001-1473 2.0 kVA
ETI0001-1473AA 2.0 kVA
ETI0001-1473AF 2.0 kVA
ETI0001-1473A 2.0 kVA
ETI0001-1473B 2.0 kVA
ETI0001-1474 2.0 kVA
ETI0001-1479 1.0 kVA
ETI0001-1482 2.0 kVA
ETI0001-1483 2.0 kVA
ETI0001-1486 2.0 kVA

Part Number: ETI0001-1479 
Rugged MilSpec 1000VA Integrated
Rackmount UPS and Intelligent
Power Distribution Unit Combination

Navy PowerStationÔ Mil Spec N5 Configuration
1000 VA Rugged Rack Mount Isolated UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit
With Drip Proof Front Panel, Shallow Depth

ETI0001-1479 Rugged MilSpec UPS and PDU Standard Front
ETI0001-1479 Rugged MilSpec UPS and PDU Standard Front 
Panel Layout

ETI0001-1479 Rugged MilSpec UPS and PDU Standard Rear
ETI0001-1479 Rugged MilSpec UPS and PDU Standard Rear 
Panel Layout


Optional ETI0001-0876 UPS and PDU Remote Control Panel in 1U

The field proven PowerStation™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The ETI0001-1479 does not require a separate PDU since the PDU functions are already integrated into the UPS module. This saves rack space, cabling and expense while improving overall reliability.

The heavy-duty chassis occupies only 3U (5.25”) of rack space while delivering up to 1000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. Rear shock isolation/alignment bushings off load the slides when the unit is fully engaged.

The internal shielded input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and optional autoranging international input voltages (230 VAC, OCONUS). Special EMI/RFI filters and input power factor correction minimize both input current and harmonics. The input circuit breaker and the galvanic isolation transformer all provide a  double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not consistent. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments.. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus battleshort override. The display and control panel can be mounted remotely in the rack at eye level, or on the keyboard console, or on the unit front panel with only a logic level cable connection. 

The rear panel provides locking connectors for the input and output power with various optional configurations available. The output connectors are standard NEMA 5-15R receptacles with stainless steel cable restraints. This reverse air flow version draws air through the front and exhausts out the rear vent into the rack. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60-hertz.  The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. The UPS Remote Control and PDU Remote Control connectors provide an interface to optional remote display/control panels. 

See the Power Distribution Units section for a listing of stand alone PDUs. See the N3 Series for a version of this UPS without the integrated PDU and remote control.

Overall, the PowerStation line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N: ETI0001-1479

AC OUTPUT
Output voltage: 120 VAC true sinewave std, up to 600 VAC optional
Output rating: UPS 1000 VA in 3U chassis x 18.5" deep 0.65-0.75 pf std, 
optional configurations to 24,000 VA
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 2.5% synchronized to utility
60 Hz ± 1.0% w/ utility not available

400 or 1000 Hz output available as an option
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: 120 VAC, optional up to 600 VAC, up to 440 Hz
Input voltage tolerance: UPS +15% -25% of nominal input rating
Input/output isolation: 1000 VA,>120 dB common mode,<1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole 100 G shock rated breaker w/ UPS fuse
Optional cold start to turn on w/o AC present
Input power connection: MS 3102A-22-2P, 3 pin, threaded locking
BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal DC protection: Front panel mounted fuse (F1)
Internal battery time: 8+ minutes @ 100% load, 20+ minutes @ 50%
Internal battery recharge: Recharged to nominal in 8 hours
DISTRIBUTION PANEL
Output circuits: Six controlled outputs w/2 pole solidstate relays
Output control: Local/remote control panel w/rocker switches
Thermal and remote interlock ON/OFF control
Output receptacles: (6) MS / NEMA 5-15R threaded locking, various options
MECHANICAL
Dimensions ( H x D x W ): 5.25 (3U) x 18.5 x 19.0 in (178x470x483mm)
Rack Slide Mount Patterns: Jonathan or General Devices patterns
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 95 lb. (43 kg) UPS
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to sides
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C)
Operating temperature: 32° to 122° F ambient ( 0° to 50° C)
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 10,000 ft (3,048 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC, Class A; EN55022; MIL STD 461
OPTIONAL ACCESSORIES
  Autoranging International Input, Cold Start, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP portTransport Cases, Slides and Mounting Kits

This page was last modified on: February 18, 2009
The N5 is one of the most popular configurations for new programs!

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Have an engineer contact me
Have a salesperson contact me
I prefer to be contacted by Email   Telephone  Fax  Regular mail
My requirement is immediate  1-3 months  3-6 months  Future

Name
Title
Company
Address
Email
Phone
Fax

To Better Help
You, Please
Describe Your
Requirements

The N5 is one of the most popular configurations for new programs!

Home Up

Send questions or comments about this web site to webmaster@ruggedsystems.com.
Copyright © 1991- 2009 Energy Technologies, Inc. All Rights Reserved. Last modified: February 18, 2009

1stEnergy™, 1stPower™, 24-7Backup™, 911power™, AC24-7™, ACanytime™, ACanywhere™, ACbackup™, ACintegrity™, AirborneBackup™, AirbornePower™, ArmyBackup™, BackupAC™, BackupSource™, BackupTheWeb™, BattlePower™, BlackoutPrevention™, BusinessBackUPS™, cleanUPS™, ControllingPower™, DC24-7™, DCbackup™, DCintegrity™, EcoPowerSource™, eDocsPort™, EnergyTech™, ETI™, ExtremePowerSource™, FuelCellUPS™, GlobalPowerSource™, GlobalUPS™, HomelandBackup™, HomelanSecurity24-7™, ImprovedPower™, IndustrialBackup™, InfoBackup™,  IntelligentUPS™, InternetPowerManager™, LabPower™, LabUPS™, LightUPS™, KnowPower™, MarineCorpBackup™, MarineCorpPower™, MedicalAC™, MedicalBackup™, MilitaryBackup™, NavigationPower™, NavyPower™, NetworkPowerManager™, NonStopAC™, OfficeUPS™, OnsiteBackup™, openUPS™, PersonalSource™, PetroChemPower™, PipelinePower™, PortablePowerPlant™, PoweringTheNet™, PowerProtection™, PowerSecurity™, PowerStatus™, PreventingBlackouts™, RedundantPower™, RenewableSource™,  RuggedPower™, RuggedSystems™, SCADApower™, SecurityGatePower™, ShipboardPower™, SignalBackup™, SolarBackup™, SolarPowerSource™, TacticalComputers™, TacticalComputerWorkstations™, TacticalOffice™, TelecomBackup™, TelecomPowerSource™, ThePowerConnection™, TrafficBackup™, TrafficSignalBackup™, UPStart™, UtilityBackup™, windUPS™, WarfighterBackup™, WarfighterPower™, and WorldPower™ are trademarks of Energy Technologies, Inc.

Diplomatic Power®, Extreme UPS®, Industrial Power Source®, Military Power®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, TacticalPower®, Tactical Power Plant®, Tactical Solar® and Tactical UPS® are registered trademarks of Energy Technologies, Inc.

Legal Statements